CVE-2018-25138: FLIR AX8 Thermal Camera 1.32.16 Hard-Coded Credentials Authentication Bypass
FLIR Systems · FLIR AX8 Thermal Camera
Affected: FLIR Systems FLIR AX8 Thermal Camera · Exploitation: unlikely (under 1%)
Not in CyberSIXT coverage yet: no article names this CVE. This page shows the public record.
Higher than 50% of scored CVEs
DescriptionCVE.org
FLIR AX8 Thermal Camera 1.32.16 contains hard-coded SSH and web panel credentials that cannot be changed through normal camera operations. Attackers can exploit these persistent credentials to gain unauthorized shell access and login to multiple camera interfaces using predefined username and password combinations.
Affected products1
From the CVE record. A product or version that is not listed is unknown, not unaffected.
- FLIR Systems · FLIR AX8 Thermal Camera1.32.16
On the Atlas
Every published CVE is on the CyberSIXT Atlas, grouped by weakness, vendor and month.
- Exploitation
- Unlikely (under 1%). EPSS under 1%, or no score yet.
- CISA KEV
- Not listed
- Public check
- No public nuclei template
- Vendor
- FLIR Systems
- Published
- December 2025
CoverageNo articles yet