CVE-2019-13924: Siemens SCALANCE S602 vulnerability
Siemens · SCALANCE S602
Affected: Siemens SCALANCE S602 · Exploitation: unlikely (under 1%)
Not in CyberSIXT coverage yet: no article names this CVE. This page shows the public record.
Higher than 57% of scored CVEs
Not scored yet. The CVE record carries no CVSS score.
DescriptionCVE.org
A vulnerability has been identified in SCALANCE S602 (All versions < V4.1), SCALANCE S612 (All versions < V4.1), SCALANCE S623 (All versions < V4.1), SCALANCE S627-2M (All versions < V4.1), SCALANCE X-200 switch family (incl. SIPLUS NET variants) (All versions < 5.2.4), SCALANCE X-200IRT switch family (incl. SIPLUS NET variants) (All versions < V5.5.0), SCALANCE X-200RNA switch family (All versions < V3.2.7), SCALANCE X-300 switch family (incl. X408 and SIPLUS NET variants) (All versions < 4.1.3). The device does not send the X-Frame-Option Header in the administrative web interface, which makes it vulnerable to Clickjacking attacks. The security vulnerability could be exploited by an attacker that is able to trick an administrative user with a valid session on the target device into clicking on a website controlled by the attacker. The vulnerability could allow an attacker to perform administrative actions via the web interface.
Affected products8
From the CVE record. A product or version that is not listed is unknown, not unaffected.
- Siemens · SCALANCE S602All versions < V4.1
- Siemens · SCALANCE S612All versions < V4.1
- Siemens · SCALANCE S623All versions < V4.1
- Siemens · SCALANCE S627-2MAll versions < V4.1
- Siemens · SCALANCE X-200 switch family (incl. SIPLUS NET variants)All versions < 5.2.4
- Siemens · SCALANCE X-200IRT switch family (incl. SIPLUS NET variants)All versions < V5.5.0
- Siemens · SCALANCE X-200RNA switch familyAll versions < V3.2.7
- Siemens · SCALANCE X-300 switch family (incl. X408 and SIPLUS NET variants)All versions < 4.1.3
On the Atlas
Every published CVE is on the CyberSIXT Atlas, grouped by weakness, vendor and month.
- Exploitation
- Unlikely (under 1%). EPSS under 1%, or no score yet.
- CISA KEV
- Not listed
- Public check
- No public nuclei template
- Vendor
- Siemens
- Published
- February 2020
CoverageNo articles yet
No CyberSIXT article names CVE-2019-13924 yet, so there is no coverage timeline, action brief or change log for it. Everything on this page comes from the public CVE record, CISA KEV, EPSS and the nuclei template index. Search the archive or see the CVEs in the news.