Skip to content
Sign in
CVE-2022-363627.5HighCWE-20

CVE-2022-36362: Siemens LOGO! 12/24RCE vulnerability

Siemens · LOGO! 12/24RCE

Affected: Siemens LOGO! 12/24RCE · Exploitation: possible (1 to 10%)

Not in CyberSIXT coverage yet: no article names this CVE. This page shows the public record.

1.0%probability of exploitation in the next 30 days
64th percentile
050100

Higher than 64% of scored CVEs

7.5HighCVSS 3.1
LowHigh

DescriptionCVE.org

A vulnerability has been identified in LOGO! 12/24RCE (6ED1052-1MD08-0BA1) (All versions), LOGO! 12/24RCE (6ED1052-1MD08-0BA2) (All versions), LOGO! 12/24RCEo (6ED1052-2MD08-0BA1) (All versions), LOGO! 12/24RCEo (6ED1052-2MD08-0BA2) (All versions), LOGO! 230RCE (6ED1052-1FB08-0BA1) (All versions), LOGO! 230RCE (6ED1052-1FB08-0BA2) (All versions), LOGO! 230RCEo (6ED1052-2FB08-0BA1) (All versions), LOGO! 230RCEo (6ED1052-2FB08-0BA2) (All versions), LOGO! 24CE (6ED1052-1CC08-0BA1) (All versions), LOGO! 24CE (6ED1052-1CC08-0BA2) (All versions), LOGO! 24CEo (6ED1052-2CC08-0BA1) (All versions), LOGO! 24CEo (6ED1052-2CC08-0BA2) (All versions), LOGO! 24RCE (6ED1052-1HB08-0BA1) (All versions), LOGO! 24RCE (6ED1052-1HB08-0BA2) (All versions), LOGO! 24RCEo (6ED1052-2HB08-0BA1) (All versions), LOGO! 24RCEo (6ED1052-2HB08-0BA2) (All versions), SIPLUS LOGO! 12/24RCE (6AG1052-1MD08-7BA1) (All versions), SIPLUS LOGO! 12/24RCE (6AG1052-1MD08-7BA2) (All versions), SIPLUS LOGO! 12/24RCEo (6AG1052-2MD08-7BA1) (All versions), SIPLUS LOGO! 12/24RCEo (6AG1052-2MD08-7BA2) (All versions), SIPLUS LOGO! 230RCE (6AG1052-1FB08-7BA1) (All versions), SIPLUS LOGO! 230RCE (6AG1052-1FB08-7BA2) (All versions), SIPLUS LOGO! 230RCEo (6AG1052-2FB08-7BA1) (All versions), SIPLUS LOGO! 230RCEo (6AG1052-2FB08-7BA2) (All versions), SIPLUS LOGO! 24CE (6AG1052-1CC08-7BA1) (All versions), SIPLUS LOGO! 24CE (6AG1052-1CC08-7BA2) (All versions), SIPLUS LOGO! 24CEo (6AG1052-2CC08-7BA1) (All versions), SIPLUS LOGO! 24CEo (6AG1052-2CC08-7BA2) (All versions), SIPLUS LOGO! 24RCE (6AG1052-1HB08-7BA1) (All versions), SIPLUS LOGO! 24RCE (6AG1052-1HB08-7BA2) (All versions), SIPLUS LOGO! 24RCEo (6AG1052-2HB08-7BA1) (All versions), SIPLUS LOGO! 24RCEo (6AG1052-2HB08-7BA2) (All versions). Affected devices do not conduct certain validations when interacting with them.

Affected products20

From the CVE record. A product or version that is not listed is unknown, not unaffected.

  • Siemens · LOGO! 12/24RCEAll versions
  • Siemens · LOGO! 12/24RCEAll versions
  • Siemens · LOGO! 12/24RCEoAll versions
  • Siemens · LOGO! 12/24RCEoAll versions
  • Siemens · LOGO! 230RCEAll versions
  • Siemens · LOGO! 230RCEAll versions
  • Siemens · LOGO! 230RCEoAll versions
  • Siemens · LOGO! 230RCEoAll versions
  • Siemens · LOGO! 24CEAll versions
  • Siemens · LOGO! 24CEAll versions
  • Siemens · LOGO! 24CEoAll versions
  • Siemens · LOGO! 24CEoAll versions
  • Siemens · LOGO! 24RCEAll versions
  • Siemens · LOGO! 24RCEAll versions
  • Siemens · LOGO! 24RCEoAll versions
  • Siemens · LOGO! 24RCEoAll versions
  • Siemens · SIPLUS LOGO! 12/24RCEAll versions
  • Siemens · SIPLUS LOGO! 12/24RCEAll versions
  • Siemens · SIPLUS LOGO! 12/24RCEoAll versions
  • Siemens · SIPLUS LOGO! 12/24RCEoAll versions

On the Atlas

Every published CVE is on the CyberSIXT Atlas, grouped by weakness, vendor and month.

Open the Atlas
Exploitation
Possible (1 to 10%). EPSS between 1% and 10%.
CISA KEV
Not listed
Public check
No public nuclei template
Vendor
Siemens
Published
October 2022

CoverageNo articles yet

No CyberSIXT article names CVE-2022-36362 yet, so there is no coverage timeline, action brief or change log for it. Everything on this page comes from the public CVE record, CISA KEV, EPSS and the nuclei template index. Search the archive or see the CVEs in the news.

References