Skip to content
Connect AISign inSign up free
CVE-2023-43467.5HighCWE-645

CVE-2023-4346: KNX Association KNX Protocol Connection Authorization Option 1 Overly Restrictive Account Lockout Mechanism Vulnerability

KNX Association · KNX Protocol Connection Authorization Option 1

No fix listed · Affected: KNX Association KNX Protocol Connection Authorization Option 1 · Exploitation: in CISA KEV since 15 Jul

Verdict

Patch nowAttackers are using it: in CISA KEV since 15 Jul.

  • YesAttacks seen: in CISA KEV since 15 Jul
  • NoPublic exploit code
  • 1.3%Chance of exploitation in 30 days, higher than 71% of scored CVEs
  • NoFix available: No fix on record
How we decide

Patch now: attacks are on record (CISA KEV, the EU exploited list, CISA marking exploitation active, or a report of exploitation), or exploit code is public for a flaw reachable over the network with no login that has exploit odds of 10% or more, or is rated critical with odds of at least 1%. Patch this cycle: any other public exploit code, scanning observed, or exploit odds of 10% or more. Routine: a fix exists and none of those. No verdict yet: no fix on record and nothing else known. The verdict says how soon to act, not how severe the flaw is, and it changes when these facts change.

What it isNVD

KNX devices that use KNX Connection Authorization and support Option 1 are, depending on the implementation, vulnerable to being locked and users being unable to reset them to gain access to the device.

The BCU key feature on the devices can be used to create a password for the device, but this password can often not be reset without entering the current password.

If the device is configured to interface with a network, an attacker with access to that network could interface with the KNX installation, purge all devices without additional security options enabled, and set a BCU key, locking the device.

Even if a device is not connected to a network, an attacker with physical access to the device could also exploit this vulnerability in the same way.

Exploit requirementsfrom the CVSS 3.1 vector

Where from
Remotely, over the network
Login
None needed
User action
None needed
Conditions
None stated in the score

Also needed, according to the published text

  • The attacker must have access to the network the device is configured to interface with“If the device is configured to interface with a network, an attacker with access to that network could interface with the KNX installation” · the CVE record
  • The attacker must have physical access to the device if it is not connected to a network“Even if a device is not connected to a network, an attacker with physical access to the device could also exploit this vulnerability in the same way.” · the CVE record

Federal deadline

CISA KEV · added 15 Jul · catalogue entry

Passed 121 days ago

1.3%probability of exploitation in the next 30 days
71st percentile
050100

Higher than 71% of scored CVEs

7.5HighCVSS 3.1
LowHigh
ExploitationIn CISA KEV

ExploitationIn CISA KEV

  1. In CISA KEVCISA KEV catalogue15 Jul

Not seen so far: exploited (reported) · scanning observed · proof of concept public.

Weakness and public checksOverly Restrictive Account Lockout Mechanism

Weakness and public checks

Public check
No public nuclei template
Weakness
Overly Restrictive Account Lockout Mechanism · Authentication
CISA required actionFrom the KEV catalogue

CISA required action

Apply mitigations in accordance with vendor instructions, ensuring compliance with CISA’s BOD 26-04 Prioritizing Security Updates Based on Risk (see URL in Notes) guidance and CISA’s “Forensics Triage Requirements” (see URL in Notes). Follow applicable BOD 26-04 guidance for cloud services or discontinue use of the product if mitigations are unavailable. Stakeholders are responsible for evaluating each asset's internet exposure and ensuring adherence to BOD 26-04 patching guidelines.
Related CVEsKNX Protocol Connection Authorization Option 1

Other CVEs in KNX Protocol Connection Authorization Option 1

Every published CVE for KNX Association KNX Protocol Connection Authorization Option 1, by how far exploitation has gone. This one is among them.

As a list
Other CVEs in KNX Protocol Connection Authorization Option 1: each mark is one CVE.Drag to move · Ctrl + scroll to zoom · a mark opens that CVE
What changed1 change, latest 15 Jul

What changed

  1. CISA added it to the KEV catalogue CISA
Coverage3 articles · 2 outlets

Coverage3 articles · 2 outlets

One row per outlet, in order of first report. First in our coverage: CISA, 15 Jul.

Full timeline
Quiet for 19 weekslast report 17 Jul3 articles2 outlets
15 Jul · CISA first30 Aug22 Sep15 Oct7 NovNow
  • Wed 15 Jul, 22:31 UTC. CISA, first report. CISA alerts on active KNX flaw CVE‑2023‑4346, urges action. Cites a CVE in CISA KEV.
  • Wed 15 Jul, 23:14 UTC. CISA. CISA alerts on active KNX flaw CVE‑2023‑4346, urges action. Cites a CVE in CISA KEV.
  • Fri 17 Jul, 08:41 UTC. Security Affairs, its first report on the story. U.S. CISA adds KNX Association KNX Protocol Connection Authorization Option 1 and Oracle flaws to its Known Exploited Vulnerabilities catalog. Cites a CVE in CISA KEV.
All coveragerunning total3CISA2Security Af…116 Jul31 Aug16 OctNow
  • First report
  • Article
  • Official notice
  • Running total

Added to CISA KEV

Show as table
  1. CISA alerts on active KNX flaw CVE‑2023‑4346, urges action
    CISA · official notice · first in our coverage

New articles also arrive in the RSS feed.

References5 links

References