CVE-2024-43648: Authenticated command injection via <redacted>.exe <redacted> parameter
Iocharger · Iocharger firmware for AC models
Vendor fix available · Affected: Iocharger firmware for AC models · Exploitation: possible (1 to 10%)
Not in CyberSIXT coverage yet: no article names this CVE. This page shows the public record.
Higher than 79% of scored CVEs
DescriptionCVE.org
Command injection in the <redacted> parameter of a <redacted>.exe request leads to remote code execution as the root user. This issue affects Iocharger firmware for AC models before version 24120701. Likelihood: Moderate – This action is not a common place for command injection vulnerabilities to occur. Thus, an attacker will likely only be able to find this vulnerability by reverse-engineering the firmware or trying it on all <redacted> fields. The attacker will also need a (low privilege) account to gain access to the <redacted> binary, or convince a user with such access to execute a payload. Impact: Critical – The attacker has full control over the charging station as the root user, and can arbitrarily add, modify and delete files and services. CVSS clarification. The attack can be executed over any network connection the station is listening to and serves the web interface (AV:N), and there are no additional security measure sin place that need to be circumvented (AC:L), the attack does not rely on preconditions (AT:N). The attack does require authentication, but the level of authentication is irrelevant (PR:L), it does not require user interaction (UI:N). If is a full system compromise, potentially fully compromising confidentiality, integrity and availability of the devicer (VC:H/VI:H/VA:H). A compromised charger can be used to "pivot" onto networks that should otherwise be closed, cause a low confidentiality and interity impact on subsequent systems. (SC:L/SI:L/SA:H). Because this device is an EV charger handing significant amounts of power, we suspect this vulnerability can have a safety impact (S:P). The attack can be automated (AU:Y).
Affected products1
From the CVE record. A product or version that is not listed is unknown, not unaffected.
- Iocharger · Iocharger firmware for AC modelsbefore 24120701
On the Atlas
Every published CVE is on the CyberSIXT Atlas, grouped by weakness, vendor and month.
- Exploitation
- Possible (1 to 10%). EPSS between 1% and 10%.
- CISA KEV
- Not listed
- Public check
- No public nuclei template
- Vendor
- Iocharger
- Published
- January 2025
CoverageNo articles yet
No CyberSIXT article names CVE-2024-43648 yet, so there is no coverage timeline, action brief or change log for it. Everything on this page comes from the public CVE record, CISA KEV, EPSS and the nuclei template index. Search the archive or see the CVEs in the news.