Skip to content
Sign in
CVE-2024-540929.8CriticalCWE-1390

CVE-2024-54092: Siemens Industrial Edge Device Kit - arm64 V1.17 vulnerability

Siemens · Industrial Edge Device Kit - arm64 V1.17

Vendor fix available · Affected: Siemens Industrial Edge Device Kit - arm64 V1.17 · Exploitation: unlikely (under 1%)

Not in CyberSIXT coverage yet: no article names this CVE. This page shows the public record.

0.8%probability of exploitation in the next 30 days
56th percentile
050100

Higher than 56% of scored CVEs

9.8CriticalCVSS 3.1
LowCrit.

DescriptionCVE.org

A vulnerability has been identified in Industrial Edge Device Kit - arm64 V1.17 (All versions), Industrial Edge Device Kit - arm64 V1.18 (All versions), Industrial Edge Device Kit - arm64 V1.19 (All versions), Industrial Edge Device Kit - arm64 V1.20 (All versions < V1.20.2-1), Industrial Edge Device Kit - arm64 V1.21 (All versions < V1.21.1-1), Industrial Edge Device Kit - x86-64 V1.17 (All versions), Industrial Edge Device Kit - x86-64 V1.18 (All versions), Industrial Edge Device Kit - x86-64 V1.19 (All versions), Industrial Edge Device Kit - x86-64 V1.20 (All versions < V1.20.2-1), Industrial Edge Device Kit - x86-64 V1.21 (All versions < V1.21.1-1), Industrial Edge Own Device (IEOD) (All versions < V1.21.1-1-a), Industrial Edge Virtual Device (All versions < V1.21.1-1-a), SCALANCE LPE9413 (6GK5998-3GS01-2AC2) (All versions < V2.1), SIMATIC IPC BX-39A Industrial Edge Device (All versions < V3.0), SIMATIC IPC BX-59A Industrial Edge Device (All versions < V3.0), SIMATIC IPC127E Industrial Edge Device (All versions < V3.0), SIMATIC IPC227E Industrial Edge Device (All versions < V3.0), SIMATIC IPC427E Industrial Edge Device (All versions < V3.0), SIMATIC IPC847E Industrial Edge Device (All versions < V3.0). Affected devices do not properly enforce user authentication on specific API endpoints when identity federation is used. This could facilitate an unauthenticated remote attacker to circumvent authentication and impersonate a legitimate user. Successful exploitation requires that identity federation is currently or has previously been used and the attacker has learned the identity of a legitimate user.

Affected products19

From the CVE record. A product or version that is not listed is unknown, not unaffected.

  • Siemens · Industrial Edge Device Kit - arm64 V1.170
  • Siemens · Industrial Edge Device Kit - arm64 V1.180
  • Siemens · Industrial Edge Device Kit - arm64 V1.190
  • Siemens · Industrial Edge Device Kit - arm64 V1.20before V1.20.2-1
  • Siemens · Industrial Edge Device Kit - arm64 V1.21before V1.21.1-1
  • Siemens · Industrial Edge Device Kit - x86-64 V1.170
  • Siemens · Industrial Edge Device Kit - x86-64 V1.180
  • Siemens · Industrial Edge Device Kit - x86-64 V1.190
  • Siemens · Industrial Edge Device Kit - x86-64 V1.20before V1.20.2-1
  • Siemens · Industrial Edge Device Kit - x86-64 V1.21before V1.21.1-1
  • Siemens · Industrial Edge Own Device (IEOD)before V1.21.1-1-a
  • Siemens · Industrial Edge Virtual Devicebefore V1.21.1-1-a
  • Siemens · SCALANCE LPE9413before V2.1
  • Siemens · SIMATIC IPC BX-39A Industrial Edge Devicebefore V3.0
  • Siemens · SIMATIC IPC BX-59A Industrial Edge Devicebefore V3.0
  • Siemens · SIMATIC IPC127E Industrial Edge Devicebefore V3.0
  • Siemens · SIMATIC IPC227E Industrial Edge Devicebefore V3.0
  • Siemens · SIMATIC IPC427E Industrial Edge Devicebefore V3.0
  • Siemens · SIMATIC IPC847E Industrial Edge Devicebefore V3.0

On the Atlas

Every published CVE is on the CyberSIXT Atlas, grouped by weakness, vendor and month.

Open the Atlas
Exploitation
Unlikely (under 1%). EPSS under 1%, or no score yet.
CISA KEV
Not listed
Public check
No public nuclei template
Vendor
Siemens
Published
April 2025

CoverageNo articles yet

No CyberSIXT article names CVE-2024-54092 yet, so there is no coverage timeline, action brief or change log for it. Everything on this page comes from the public CVE record, CISA KEV, EPSS and the nuclei template index. Search the archive or see the CVEs in the news.