CVE-2025-544978.1HighCWE-732

CVE-2025-54497: Cognex In-Sight Explorer and In-Sight Camera Firmware Incorrect Permission Assignment for Critical Resource

Cognex · In-Sight 2000 series

Affected: Cognex In-Sight 2000 series · Exploitation: unlikely (under 1%)

Not in CyberSIXT coverage yet: no article names this CVE. This page shows the public record.

0.3%probability of exploitation in the next 30 days
25th percentile
050100

Higher than 25% of scored CVEs

8.1HighCVSS 3.1
LowHigh

DescriptionCVE.org

Cognex In-Sight Explorer and In-Sight Camera Firmware expose a telnet-based service on port 23 to allow management operations such as firmware upgrades and device reboots, which require authentication. A user with protected privileges can successfully invoke the SetSerialPort functionality to modify relevant device properties (such as serial interface settings), contradicting the security model proposed in the user manual.

Affected products5

From the CVE record. A product or version that is not listed is unknown, not unaffected.

  • Cognex · In-Sight 2000 seriesfrom 5.x up to and including 6.5.1
  • Cognex · In-Sight 7000 seriesfrom 5.x up to and including 6.5.1
  • Cognex · In-Sight 8000 seriesfrom 5.x up to and including 6.5.1
  • Cognex · In-Sight 9000 seriesfrom 5.x up to and including 6.5.1
  • Cognex · In-Sight Explorerfrom 5.x up to and including 6.5.1

On the Atlas

Every published CVE is on the CyberSIXT Atlas, grouped by weakness, vendor and month.

Open the Atlas
Exploitation
Unlikely (under 1%). EPSS under 1%, or no score yet.
CISA KEV
Not listed
Public check
No public nuclei template
Vendor
Cognex

CoverageNo articles yet

No CyberSIXT article names CVE-2025-54497 yet, so there is no coverage timeline, action brief or change log for it. Everything on this page comes from the public CVE record, CISA KEV, EPSS and the nuclei template index. Search the archive or see the CVEs in the news.

References