CVE-2019-6576: Siemens AG SIMATIC HMI Comfort Panels 4" - 22" vulnerability
Siemens AG · SIMATIC HMI Comfort Panels 4" - 22"
Affected: Siemens AG SIMATIC HMI Comfort Panels 4" - 22" · Exploitation: possible (1 to 10%)
Not in CyberSIXT coverage yet: no article names this CVE. This page shows the public record.
Higher than 78% of scored CVEs
DescriptionCVE.org
A vulnerability has been identified in SIMATIC HMI Comfort Panels 4" - 22" (All versions < V15.1 Update 1), SIMATIC HMI Comfort Outdoor Panels 7" & 15" (All versions < V15.1 Update 1), SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 und KTP900F (All versions < V15.1 Update 1), SIMATIC WinCC Runtime Advanced (All versions < V15.1 Update 1), SIMATIC WinCC Runtime Professional (All versions < V15.1 Update 1), SIMATIC WinCC (TIA Portal) (All versions < V15.1 Update 1), SIMATIC HMI Classic Devices (TP/MP/OP/MP Mobile Panel) (All versions). An attacker with network access to affected devices could potentially obtain a TLS session key. If the attacker is able to observe TLS traffic between a legitimate user and the device, then the attacker could decrypt the TLS traffic. The security vulnerability could be exploited by an attacker who has network access to the web interface of the device and who is able to observe TLS traffic between legitimate users and the web interface of the affected device. The vulnerability could impact the confidentiality of the communication between the affected device and a legitimate user. At the time of advisory publication no public exploitation of the security vulnerability was known.
Affected products7
From the CVE record. A product or version that is not listed is unknown, not unaffected.
- Siemens AG · SIMATIC HMI Comfort Panels 4" - 22"All versions < V15.1 Update 1
- Siemens AG · SIMATIC HMI Comfort Outdoor Panels 7" & 15"All versions < V15.1 Update 1
- Siemens AG · SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 und KTP900FAll versions < V15.1 Update 1
- Siemens AG · SIMATIC WinCC Runtime AdvancedAll versions < V15.1 Update 1
- Siemens AG · SIMATIC WinCC Runtime ProfessionalAll versions < V15.1 Update 1
- Siemens AG · SIMATIC WinCC (TIA Portal)All versions < V15.1 Update 1
- Siemens AG · SIMATIC HMI Classic Devices (TP/MP/OP/MP Mobile Panel)All versions
On the Atlas
Every published CVE is on the CyberSIXT Atlas, grouped by weakness, vendor and month.
- Exploitation
- Possible (1 to 10%). EPSS between 1% and 10%.
- CISA KEV
- Not listed
- Public check
- No public nuclei template
- Vendor
- Siemens AG
- Published
- May 2019
CoverageNo articles yet
No CyberSIXT article names CVE-2019-6576 yet, so there is no coverage timeline, action brief or change log for it. Everything on this page comes from the public CVE record, CISA KEV, EPSS and the nuclei template index. Search the archive or see the CVEs in the news.