CVE-2019-6577: Siemens AG SIMATIC HMI Comfort Panels 4" - 22" vulnerability
Siemens AG · SIMATIC HMI Comfort Panels 4" - 22"
Affected: Siemens AG SIMATIC HMI Comfort Panels 4" - 22" · Exploitation: unlikely (under 1%)
Not in CyberSIXT coverage yet: no article names this CVE. This page shows the public record.
Higher than 59% of scored CVEs
Not scored yet. The CVE record carries no CVSS score.
DescriptionCVE.org
A vulnerability has been identified in SIMATIC HMI Comfort Panels 4" - 22" (All versions < V15.1 Update 1), SIMATIC HMI Comfort Outdoor Panels 7" & 15" (All versions < V15.1 Update 1), SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 und KTP900F (All versions < V15.1 Update 1), SIMATIC WinCC Runtime Advanced (All versions < V15.1 Update 1), SIMATIC WinCC Runtime Professional (All versions < V15.1 Update 1), SIMATIC WinCC (TIA Portal) (All versions < V15.1 Update 1), SIMATIC HMI Classic Devices (TP/MP/OP/MP Mobile Panel) (All versions). The integrated web server could allow Cross-Site Scripting (XSS) attacks if an attacker is able to modify particular parts of the device configuration via SNMP. The security vulnerability could be exploited by an attacker with network access to the affected system. Successful exploitation requires system privileges and user interaction. An attacker could use the vulnerability to compromise confidentiality and the integrity of the affected system. At the stage of publishing this security advisory no public exploitation is known.
Affected products7
From the CVE record. A product or version that is not listed is unknown, not unaffected.
- Siemens AG · SIMATIC HMI Comfort Panels 4" - 22"All versions < V15.1 Update 1
- Siemens AG · SIMATIC HMI Comfort Outdoor Panels 7" & 15"All versions < V15.1 Update 1
- Siemens AG · SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 und KTP900FAll versions < V15.1 Update 1
- Siemens AG · SIMATIC WinCC Runtime AdvancedAll versions < V15.1 Update 1
- Siemens AG · SIMATIC WinCC Runtime ProfessionalAll versions < V15.1 Update 1
- Siemens AG · SIMATIC WinCC (TIA Portal)All versions < V15.1 Update 1
- Siemens AG · SIMATIC HMI Classic Devices (TP/MP/OP/MP Mobile Panel)All versions
On the Atlas
Every published CVE is on the CyberSIXT Atlas, grouped by weakness, vendor and month.
- Exploitation
- Unlikely (under 1%). EPSS under 1%, or no score yet.
- CISA KEV
- Not listed
- Public check
- No public nuclei template
- Vendor
- Siemens AG
- Published
- May 2019
CoverageNo articles yet
No CyberSIXT article names CVE-2019-6577 yet, so there is no coverage timeline, action brief or change log for it. Everything on this page comes from the public CVE record, CISA KEV, EPSS and the nuclei template index. Search the archive or see the CVEs in the news.